A junction box is the central point where cables from sockets, switches and lights meet. This is the place where conductors are connected and split between circuits. Most electrical faults start with a bad joint inside the box: overheating, arcing, unstable contact, short circuits. In older buildings on Targowek and Praga we often open junction boxes and find twisted connections wrapped in tape that has been there for decades — asking for problems.

The cost is based on how many connections are inside the box and how complicated the circuit is. A basic box with 2–3 cables is straightforward work. A more involved box with two-way switching and several groups needs more time. All electrical service prices are listed in the table.


Warning: work inside a junction box means dealing with several circuits at the same time. One wrong connection can take out multiple points or cause a fire. Do not risk it — call an electrician.


A client on Praga Polnoc lost the hallway light and one socket in the living room. The breaker had not tripped. We located the junction box behind a wardrobe — inside there were three twisted joints wrapped in tape from the 1980s. One aluminium-to-copper twist had completely oxidised and lost contact. We took all the joints apart, stripped the cables and reconnected everything with WAGO connectors (using aluminium paste). Every circuit tested properly — both the light and socket were working. The client then asked us to inspect a second box in the bedroom — we redid that one as well. The whole job took about an hour (compatible with Legrand, Schneider Electric, ABB and similar).
Yes, but only with specialist connectors (WAGO with paste, split bolts, or bolted joints with washers). Twisting them directly together is prohibited — corrosion will ruin the joint.
A twisted joint without extra treatment (solder, crimp) works loose over time, oxidises and overheats. Codes do not allow untreated twisted joints.
Most often near the ceiling, above a switch or door. Sometimes it is plastered over and cannot be seen — the technician will find it with a detector.
One box — 20–40 minutes. If old twists have to be dismantled and rewired — up to an hour.
If it is cracked, too small for the number of connections, or will not close — yes.

We wire and rewire junction boxes all over Warsaw. We replace twisted joints with proper connectors, fix broken connections and test circuits. Get in touch — we will come over and put it right.